How to wire a bathroom extractor fan with a timer and isolator

Wire a bathroom extractor fan with an over run timer to a three pole fan isolator and a pull cord switch. It suits DIYers who are comfortable working with mains wiring and have the fan and switches ready.

YouTube video: How to wire bathroom fan Extractor fan with timer and Fan Isolator

YouTube’s video details do not confirm captions. Check CC in the player for available tracks.

Video length
9 min 19 s
Time to do it
45 minutes
Difficulty
Medium
Steps
8

What you need

Steps

  1. Switch off the power at the consumer unit and prove the circuit is dead with a voltage tester before you touch any wires.

  2. Mount the fan on the wall or ceiling and the three pole isolator where you can reach it for servicing.

  3. Run the permanent live, switched live and neutral from the pull cord switch to the isolator, then from the isolator to the fan.

  4. Connect the permanent live to the timer terminal so the fan can run on after the light goes off.

  5. Connect the switched live from the pull cord switch to the fan's trigger terminal.

  6. Wire the neutral to the fan's neutral terminal and the earth to the earth point.

  7. Fit the three pole isolator so it breaks all three conductors, then replace the covers and tighten the cable clamps.

  8. Restore the power and pull the cord to check the fan starts and keeps running for the timer period.

Tips and common mistakes

The isolator must switch all three poles so the fan can be made safe for cleaning or repair.

Set the over run timer to the time you want the fan to keep running after the light is switched off.

If the fan runs on when the light is off, check that the permanent live and switched live are not swapped.

Questions

Why does my fan need a permanent live?

The over run timer uses the permanent live to keep the fan running after the switched live goes off. Without it the fan stops as soon as the light goes out.

Can I wire the fan without an isolator?

It works, but a three pole isolator lets you cut all three conductors for safe servicing. Fit one if you can reach the wiring.

How long should the timer run?

Set it to suit the room, often a few minutes after the light goes off. Check the fan's instructions for the timer range.

The notes are drafted automatically from video details and general task knowledge. How the guide was prepared