How to replace a wall extractor fan with a Vent-Axia Silhouette

Swap an old, noisy wall extractor fan for a Vent-Axia Silhouette model. The job suits a confident DIYer who is happy to isolate the power and reconnect three wires. You need a replacement fan, a screwdriver and a way to test that the power is off.

YouTube video: How to replace a wall extractor fan | vent-Axia Silhouette

YouTube’s video details do not confirm captions. Check CC in the player for available tracks.

Video length
7 min 20 s
Time to do it
45 minutes
Difficulty
Medium
Steps
8

What you need

Steps

  1. Switch off the fan at the wall switch and turn off the circuit at the consumer unit. Test the terminals with a voltage tester to confirm the power is dead.

  2. Remove the front cover and any screws holding the old fan body to the wall. Keep the screws in a cup so you do not lose them.

  3. Note how the three wires connect: permanent live, switched live and neutral. Take a photo before you disconnect anything.

  4. Disconnect the wires and pull the old fan out of the wall. Check the duct and clear any dust or debris blocking the opening.

  5. Hold the new Vent-Axia Silhouette against the wall and line up its screw holes with the old fixing points. Mark new holes if they do not match.

  6. Connect the wires to the matching terminals on the new fan, following the wiring diagram on the unit. Tighten each screw firmly.

  7. Fix the fan body to the wall with the screws, then fit the front cover and any filter as the instructions show.

  8. Restore the power and test the fan on both settings. Check that air flows out and the blades spin freely without rubbing.

Tips and common mistakes

Never rely on the wall switch alone; isolate the circuit at the consumer unit before touching wires.

If the old fan used a different wiring layout, check the new fan's diagram rather than copying the old connections.

Seal gaps around the fan body to stop draughts and damp air coming back through the wall.

Questions

Do I need an electrician to replace an extractor fan?

Not always. If your fan is on a simple three-wire circuit and you can isolate it safely, you can do it yourself. Call a qualified electrician if you are unsure about the wiring.

Can I fit a Vent-Axia Silhouette in the same hole as my old fan?

Often yes, but check the cut-out and screw spacing first. If they differ, you may need to drill new fixing holes or adjust the opening.

Why is my new fan noisy or not spinning?

Check that the blades are clear of the housing and the wires are not touching them. Also confirm the live and switched live wires are in the right terminals.

The notes are drafted automatically from video details and general task knowledge. How the guide was prepared

Report a correction