How to bleed a radiator and get your home ready for winter

Three small jobs that make a house warmer before winter: bleeding the radiators, sealing a draughty window and setting the ceiling fan for cold weather. It suits any beginner with a radiator key and a free hour. Work with the heating off and the radiators cool.

YouTube video: 3 Small Jobs to Get Your Home Ready for Winter | How Do

Captions are available. Use CC in the YouTube player.

8 chapters. Tap a step to jump to it.Chapters from the creator
Choose a chapter (8)
Video length
8 min 26 s
Time to do it
1 hour
Difficulty
Easy
Steps
9

What you need

Steps

  1. Turn the heating off and wait until the radiators are cool to the touch. Hot water from the bleed valve can scald you.

  2. Hold a cloth or small bowl under the bleed valve at the top of the radiator. Fit the radiator key and turn it anticlockwise about a quarter turn.

  3. You will hear a hiss as trapped air escapes. Close the valve as soon as steady water, not air, comes out.

  4. Check the boiler pressure gauge once the radiators are done. If it sits below the range in your manual, top up through the filling loop the way the manual shows.

  5. If the pressure keeps dropping, stop and call a qualified heating engineer. In the UK, choose a Gas Safe registered one.

  6. For a draughty window, clean and dry the frame, then press self-adhesive foam or brush strip into the gap. On sash windows, fit a brush seal in the parting bead.

  7. Set the ceiling fan to clockwise for winter and run it on low speed. That pulls cool air up and pushes warm air back down to where you sit.

  8. Fit a chimney draught excluder only when the fire is out, and take it out before you light a fire again.

  9. Check that trickle vents, airbricks and extractor fans are clear. Test your smoke and carbon monoxide alarms and try the thermostat one degree lower.

Tips and common mistakes

Bleed a radiator again midwinter if the top stays cold while the bottom heats up.

Never block air vents or the air supply to open fires, flues or gas appliances.

A radiator that is cold at the bottom usually has sludge, not air, so ask an engineer about a flush.

A chimney excluder must still let some air through, and it comes out before any fire is lit.

Questions

How do I know a radiator needs bleeding?

It feels warm at the bottom and cold at the top, or you hear gurgling when the heating comes on. Trapped air is the usual cause.

What boiler pressure should I aim for?

Most sealed systems want about 1 to 1.5 bar when cold, but your manual gives the right figure for your boiler. Top up slowly and recheck the gauge.

Which way should a ceiling fan spin in winter?

Clockwise on a low speed. It gently moves warm air that has risen to the ceiling back down into the room.

The notes are drafted automatically from video details and general task knowledge. How the guide was prepared

Report a correction

More in Home & DIY

See all