How to test tetrahydrofuran (THF) in a QC laboratory

You will run a full quality control screen on a tetrahydrofuran sample, from appearance and identity through water content, colour, acidity and residue. It suits QC chemists, freshers and chemistry students working with an approved SOP. You need a GC-FID, a Karl Fischer titrator and the current safety data sheet before you start.

YouTube video: THF ANALYSIS TEST PROCEDURE SOP | COMPLETE QC LABORATORY GUIDE

Caption availability is unknown. Check the CC control in the YouTube player.

Video length
1 min 34 s
Time to do it
2 hours
Difficulty
Medium
Steps
10

What you need

Steps

  1. Read the SDS and the approved SOP for THF before you open the bottle. Note the flammability and peroxide warnings and set up your work in a fume hood.

  2. Check appearance by pouring the sample into a clean, dry glass vial. Look at it against a white background in good light and record colour and clarity.

  3. Identify the material by FTIR. Run an ATR or thin film spectrum and compare the main peaks with a reference spectrum of THF.

  4. Confirm identity and purity by GC-FID using your validated method. Record the retention time and the peak area percent for the main peak.

  5. Measure water content by Karl Fischer titration. Weigh a known amount of sample, titrate to the endpoint and calculate the result in ppm or percent.

  6. Test colour by the APHA or Hazen method. Compare the sample with the platinum-cobalt standards and report the matching number.

  7. Check peroxide content with the method in your SOP, such as an iodometric titration. If the result is high, stop and follow your site procedure.

  8. Titrate acidity against a standard sodium hydroxide or KOH solution and report the result as percent acid.

  9. Determine residue on evaporation by evaporating a weighed portion on a water bath, then drying and weighing the residue.

  10. Measure density or specific gravity, then record every result in your notebook or LIMS and compare each one against the specification.

Tips and common mistakes

Keep THF away from heat, sparks and open flames, and bond and ground containers when you pour.

Never evaporate or distil THF that may hold peroxides, and never distil it to dryness.

Run a blank and a standard alongside each batch so you can trust the titration results.

Use fresh Karl Fischer reagent and check the drift rate before you start titrating.

Questions

Why does THF need a peroxide test?

THF forms peroxides slowly during storage, and these can explode when the solvent is concentrated or heated. Testing before use tells you whether the batch is safe to handle.

Which test confirms the identity of THF?

FTIR and GC both work. FTIR shows the characteristic absorbance pattern, while GC gives a retention time that matches a reference standard.

How much sample do I need?

Usually a few millilitres per test is enough, but the exact amount depends on your SOP and the sensitivity of each method. Weigh samples accurately for Karl Fischer and residue tests.

The notes are drafted automatically from video details and general task knowledge. How the guide was prepared

Report a correction

More in School & Learning