Fit a black IP-rated 2-gang outdoor socket onto an existing steel wire armoured (SWA) cable feed. It suits apprentices and confident DIYers who already have the cable in place and want to prepare and terminate it neatly. The cable must already be installed and isolated before you start.
YouTube video: How to Install a 2-Gang Outdoor Socket Using SWA | Apprentice Guide
YouTube’s video details do not confirm captions. Check CC in the player for available tracks.
- Video length
- 7 min
- Time to do it
- 45 minutes
- Difficulty
- Medium
- Steps
- 9
What you need
Steps
Isolate the circuit at the consumer unit and prove it is dead with a voltage tester before touching the cable.
Look at the cable and socket first. Check the SWA size, the number of cores and the gland entry points on the back of the socket.
Strip the outer sheath back far enough to fit the gland and leave the required length of inner cores to reach the terminals.
Score around the armour with the armoured slicer, then unwind and cut the wire strands cleanly so they sit in the gland.
Slide the gland body onto the cable, fit the armour ring and banjo, then tighten the gland so the armour is clamped firmly.
Remove the socket cover and fix the base to the wall with the Fisher screw set, feeding the gland through the entry hole.
Strip the inner cores, sleeve the earth, and connect live, neutral and earth to the correct terminals. Tighten each screw firmly.
Check the connections, refit the cover and tighten the gland nut so the seal grips the cable.
Restore power and test the socket with a plug-in tester before use.
Tips and common mistakes
Take your time on the gland. A rushed armour termination is the most common cause of a poor seal.
Do not over-strip the inner cores. Leave enough length to reach the terminals without strain.
Make sure the cover seal sits flat before you tighten the screws, or the IP rating is lost.
Questions
Can I do this myself?
Only if you are competent and the work meets the relevant wiring regulations. If in doubt, use a qualified electrician.
What gland do I need for SWA?
Use a proper armoured cable gland sized to the cable, such as a Storm gland, so the armour is clamped and earthed.
Do I need to isolate the power?
Yes. Isolate at the consumer unit and prove dead before working on the cable.
The notes are drafted automatically from video details and general task knowledge. How the guide was prepared