How to drain and refill a central heating system

Draining down and refilling a central heating system lets you swap radiators, valves or add inhibitor. This guide suits confident DIYers with a standard gas or oil boiler and a filling loop. You will need a hose, a bleed key and a few hours spare.

YouTube video: How to Drain and Refill Your Heating System - Quick and Easy Guide

Caption availability is unknown. Check the CC control in the YouTube player.

Video length
13 min 47 s
Time to do it
2 hours
Difficulty
Medium
Steps
10

What you need

Steps

  1. Turn the boiler off at the controls and let the system cool for at least an hour. Hot water can scald, so never drain a system that is still warm.

  2. Find the drain valve, usually at the lowest point of the pipework near a downstairs radiator or outside wall. Clear the floor and put down towels and a tub.

  3. Push the hose onto the drain valve and run the other end to an outside drain or a bucket. Secure it with a jubilee clip or hose clip so it cannot slip off.

  4. Open the drain valve with the spanner or a radiator key. Then open the bleed valves on the upstairs radiators so air gets in and the water flows out.

  5. Let the system empty completely. Open every radiator bleed valve in turn to release trapped water, then close them all again once the flow stops.

  6. Shut the drain valve firmly and remove the hose. Check the valve is fully closed before you refill, or water will pour out again.

  7. Connect the filling loop between the cold mains and the boiler, then open the valve slowly. Watch the pressure gauge and stop at around 1 to 1.5 bar.

  8. Bleed each radiator starting downstairs, then upstairs, topping up the pressure with the filling loop after each round. Close the valves when water runs steadily.

  9. Add inhibitor through a radiator bleed valve or the filling loop if you drained the system for a repair. Dose it to the amount on the bottle for your radiator count.

  10. Run the boiler and check every valve, joint and radiator for leaks. Top up the pressure to 1 to 1.5 bar once the system is warm.

Tips and common mistakes

Take a photo of the filling loop and valve positions before you start so refilling is straightforward.

Water in the system can be black and messy, so keep towels down and route the hose away from walls and paving.

If the boiler will not fire after refilling, the pressure is probably too low or air is trapped, so recheck the gauge and bleed again.

Keep water away from electrics and never work on the boiler casing itself, which is a job for a Gas Safe engineer.

Questions

Do I need to drain the whole system to change one radiator?

No. You can close both radiator valves and drain just that radiator into a tub, which saves water and time. Drain the full system only for bigger jobs like fitting new pipework or a flush.

What pressure should a combi boiler be after refilling?

Most combi boilers run best between 1 and 1.5 bar when cold. Check the manufacturer's manual, because some models specify slightly different figures.

How do I know all the air is out?

Water should run in a steady stream with no hissing or spitting when you open each bleed valve. Repeat the bleeding a day later, as air often works its way around the system.

The notes are drafted automatically from video details and general task knowledge. How the guide was prepared

Report a correction