Trapped air stops hot water from filling your baseboard unit, so the fins stay cold even with the heat on. This guide shows you how to open the bleed valve, let the air out and get the whole run heating again. It suits any homeowner with a hot water boiler system.
YouTube video: How To Bleed Trapped Air From Baseboard Heater
Caption availability is unknown. Check the CC control in the YouTube player.
- Video length
- 1 min 53 s
- Time to do it
- 20 minutes
- Difficulty
- Easy
- Steps
- 8
What you need
Steps
Turn the thermostat off and let the system cool for 15 to 20 minutes. Hot water in the loop can scald you if you open the valve too soon.
Find the bleed valve. On most baseboard units it sits at one end of the finned pipe, behind the end cap, and looks like a small slotted screw or a square plug.
Lay a towel under the valve and hold a cup or shallow bucket below it. Water and air will spit out once you open it.
Open the valve slowly, a quarter turn at a time, with the bleed key or screwdriver. You should hear a hiss as the trapped air escapes.
Let it hiss until the sound stops and a steady trickle of water runs out. That means the air is gone and the pipe is full.
Close the valve firmly but do not over-tighten it. Check for drips and wipe the area dry.
Repeat on every baseboard unit in the zone, starting with the lowest floor and working upward. Air collects at the highest points.
Check the boiler pressure gauge and top up with the fill valve if it reads low, then turn the thermostat back on and feel for even heat.
Tips and common mistakes
If a unit has no bleed valve, look for an air vent or bleeder on the boiler or at the high point of the loop instead.
Bleeding drops system pressure, so check the gauge afterwards and refill to the manufacturer's marked range.
Cold at the bottom and hot at the top usually means air, while cold at the top often points to a different problem such as a stuck zone valve.
Questions
How often should I bleed a baseboard heater?
Only when a unit stays cold or gurgles with the heat on. Once a year before heating season is plenty for most homes.
What if no water comes out when I open the valve?
The system pressure may be too low or the circulator is off. Check the boiler gauge and refill before trying again.
Do I need to shut off the boiler first?
You do not have to drain it, but turning off the thermostat and letting the water cool makes the job safer.