You'll learn how to push trapped air out of a hot water baseboard loop so rooms heat evenly and pipes stop gurgling. It suits homeowners with a hydronic system who can reach the boiler and a drain or purge valve. You need a garden hose long enough to reach a drain or outside.
YouTube video: How to Bleed AIR from Baseboard heating system
Caption availability is unknown. Check the CC control in the YouTube player.
- Video length
- 7 min 34 s
- Time to do it
- 30 minutes
- Difficulty
- Medium
- Steps
- 9
What you need
Steps
Turn the thermostat to off and let the system cool. Shut off power to the boiler at the switch if your manual says to.
Find the purge or drain valve on the return pipe near the boiler and the zone valves for each loop. Clear space and put a bucket and towels under the valve.
Screw a 50 foot garden hose onto the purge valve and run the other end to a floor drain, sink or outside. Tighten the fitting with channel locks, but do not overtighten.
Close the zone valves for every loop except the one you are purging. This forces water through that baseboard loop and pushes the air out.
Open the purge valve slowly and let water run. You will hear spitting and see bubbles at first. Keep the valve open until the flow runs steady and clear.
Watch the boiler pressure gauge while purging. Check the instructions for your exact model before choosing this setting or amount.
Close the purge valve, remove the hose and refit the brass cap. Open the other zone valves and repeat for each loop that has trapped air.
Restore the boiler power and set the thermostat to heat. Check the pressure gauge, listen for gurgling, and look for leaks at the valve and hose connection.
If a baseboard run still has a manual bleeder valve at the end, open it with the key or vent until water drips steadily, then close it.
Tips and common mistakes
Work with cool water; a boiler loop can be hot enough to scald even when the thermostat is off.
Keep brass caps and valve parts in a cup so you do not lose them when the hose is connected.
Do not drain more water than needed; long purges can drop pressure and add fresh water that contains air.
If pressure will not hold or water keeps sputtering, call a heating tech; the system may have a bigger air source or leak.
Questions
How do I know all the air is out?
The hose runs clear and steady with no spitting, the pipes stop gurgling, and the boiler gauge holds its normal cold pressure.
Do I need to purge every zone?
Yes, air can sit in any loop. Close all other zone valves and purge one loop at a time so water takes the full path.
What pressure should the boiler be at?
Check the instructions for your exact model before choosing this setting or amount.