Push mains water through each heating zone with a hose to drive trapped air out of the system, instead of opening every radiator valve by hand. It suits homes with a boiler, a yellow return ball valve and a drain service valve on each zone. Check the instructions for your exact model before choosing this setting or amount.
YouTube video: How to Bleed Radiators in Entire Heating System Quickly and Effectively
Caption availability is unknown. Check the CC control in the YouTube player.
Choose a chapter (9)
- Video length
- 2 min 32 s
- Time to do it
- 30 minutes
- Difficulty
- Medium
- Steps
- 10
What you need
Steps
Switch the boiler off at the control panel or wall switch and let the water cool before you touch any valves.
Find the return ball valve with the yellow handle on the zone you want to bleed. If that zone has its own zone valve, open it first.
Screw the bleed hose onto the service valve at the drain point and lead the other end to a drain, bucket or outside.
Open the service valve so water can leave the system through the hose.
Crack the city water fill valve open a little. Check the instructions for your exact model before choosing this setting or amount.
Let water run for 5 to 10 minutes. Hold the pressure steady until the hose stops spitting air and runs clear.
Shut the city water fill valve first, then close the service valve on the hose.
Take the hose off and refit the cap on the service valve.
Open the yellow return ball valve again so the zone can flow normally.
Move to the next zone and repeat, then refill to the normal cold pressure and switch the boiler back on.
Tips and common mistakes
Never leave the fill valve fully open and unattended. Add water in short bursts with your hand on the valve.
Check the instructions for your exact model before choosing this setting or amount.
Lay a towel under the hose connection. A few drips are normal when you disconnect.
Cold tops on radiators or gurgling after bleeding usually mean air is still being drawn in somewhere.
Questions
Do I need to bleed each radiator separately?
Not with this method. Pushing water through the zone carries the air out through the hose, so you can skip the radiator keys.
What pressure should the boiler sit at?
Check the instructions for your exact model before choosing this setting or amount.
Will this work on a combi boiler?
It suits systems with a service valve and drain point. Many combis use a filling loop instead, so check your manual first.