How to bleed a radiator to get rid of cold spots

Trapped air stops a radiator heating all the way to the top. This guide shows you how to release it with a radiator key so the whole panel warms evenly again. It suits anyone with a standard UK radiator and a bleed valve at the top corner. You only need a key and an old cloth.

YouTube video: How to Bleed a Radiator - British Gas

Caption availability is unknown. Check the CC control in the YouTube player.

Video length
1 min 17 s
Time to do it
20 minutes
Difficulty
Easy
Steps
8

What you need

Steps

  1. Check each radiator while the heating is on. If it is hot at the bottom and cold at the top, trapped air is the cause and it needs bleeding.

  2. Turn the central heating off at the controls and let the radiators cool for about 20 minutes. Hot water can scald your hands.

  3. Find the bleed valve at the top corner of the radiator. Put a rag or small towel underneath it to catch any drips.

  4. Push the radiator key onto the square spindle inside the valve. Hold the rag in one hand and the key in the other.

  5. Turn the key anticlockwise about a quarter turn. You should hear air hissing out of the valve.

  6. Hold the key steady until the hissing stops and water dribbles out smoothly, then turn the key clockwise to close the valve. Do not overtighten it.

  7. Wipe up any drips and repeat on any other radiators that are cold at the top.

  8. Turn the central heating back on and check the radiator now heats evenly from top to bottom.

Tips and common mistakes

Never bleed a radiator while the heating is running, as the water inside can be hot enough to scald you.

If a radiator is cold at the bottom instead of the top, bleeding will not fix it. That is usually sludge and needs a power flush or an engineer.

Bleed your radiators once a year, ideally before you start using the heating in autumn.

Check the boiler pressure after bleeding and top it up if the gauge has dropped below about 1 bar.

Questions

How do I know if a radiator needs bleeding?

Feel it while the heating is on. Cold at the top and warm at the bottom means trapped air. Cold at the bottom points to sludge instead, which bleeding will not solve.

What if no water comes out of the valve?

If air hisses and then nothing follows, close the valve and check the boiler pressure. Low pressure or a blocked valve needs an engineer.

Can I use a screwdriver instead of a radiator key?

Some modern valves have a slot that takes a flat screwdriver, but a proper radiator key grips the spindle better and is less likely to round it off.