Bleeding a radiator takes about 10 minutes with a radiator key, a towel and a jug. This guide walks you through releasing trapped air so the radiator heats evenly again, and covers what to check on the boiler afterwards. It suits anyone with a radiator that stays cold while the rest of the house warms up.
YouTube video: HomeLab: Cold Radiator? Fix It In 2 Mins No Plumber
Caption availability is unknown. Check the CC control in the YouTube player.
- Video length
- 2 min 2 s
- Time to do it
- 10 minutes
- Difficulty
- Easy
- Steps
- 9
What you need
Steps
Turn the heating off at the thermostat or boiler and wait 20 to 30 minutes for the radiators to cool. Hot water from the valve can scald your hands.
Put a towel on the floor under the bleed valve and hold a small jug under it. The valve sits at the top corner of the radiator, usually at one end.
Fit the radiator key onto the square spindle in the middle of the valve. A flathead screwdriver works if the slot is wide enough.
Turn the key anticlockwise a quarter to half a turn. You should hear a hiss of air escaping. Stop turning once the valve opens.
Let the air escape and keep the jug under the valve. The hiss gets weaker as the air runs out and water starts to reach the opening.
Close the valve clockwise as soon as a steady trickle of water appears. Tighten it gently, just enough to stop the flow, then dry the area.
Check the boiler pressure gauge. If it reads below 1 bar, top it up with the filling loop to between 1 and 1.5 bar.
Turn the heating back on and let it run for 10 minutes. Feel the radiator at the top and bottom to check it now heats evenly.
Work through any other cold radiators one at a time, checking the boiler pressure again after each one.
Tips and common mistakes
Bleed with the heating off and the radiators cool, so you avoid burns and stop more air being pulled in.
Open the valve only until water trickles out. Leaving it running wastes water and drops the boiler pressure.
If the radiator is still cold at the bottom after bleeding, the cause is likely sludge and it needs a flush, not more bleeding.
Keep the towel wrapped around the valve, because the water that comes out is dirty and can stain pale carpets.
Questions
Why is my radiator cold at the bottom but warm at the top?
Trapped air usually rises to the top, so a cold bottom often points to sludge or debris sitting inside the radiator. Bleed it first, and if the bottom stays cold, get the system flushed.
How do I know when the radiator is fully bled?
The hiss of air stops and a steady trickle of water comes out of the valve. Close the valve at that point.
Do I need to top up the boiler after bleeding a radiator?
Often yes. Bleeding releases water from the system, so check the pressure gauge and refill to between 1 and 1.5 bar if it has dropped.