Balancing makes every radiator heat up evenly by adjusting how much hot water each one gets. You set the lockshield valve on each radiator, starting with the one nearest the boiler. It suits any homeowner with a standard wet central heating system and needs a radiator key and a small spanner.
YouTube video: How to Balance Heating System Radiators - Plumbing Tips
Caption availability is unknown. Check the CC control in the YouTube player.
- Video length
- 4 min 53 s
- Time to do it
- 45 minutes
- Difficulty
- Easy
- Steps
- 8
What you need
Steps
Turn the heating on and let it run until all radiators are hot. Note which ones heat up fastest and which stay cold at the bottom or top.
Bleed any radiator that is cold at the top using a radiator key. Open the bleed valve until water trickles out, then close it.
Start at the radiator closest to the boiler. Open its lockshield valve fully by turning the plastic cap anticlockwise, then count the turns as you close it again.
Open the lockshield about a quarter turn to a half turn. This restricts flow so the far radiators still get hot water.
Move to the next radiator along the pipe run and repeat. Give each one slightly more opening than the last as you get further from the boiler.
Set the thermostatic radiator valve (TRV) on each radiator to a mid setting, such as 3. The TRV controls room temperature, not balancing.
Wait 20 to 30 minutes, then feel each radiator. Adjust the lockshields a little at a time until all radiators reach a similar temperature.
Write down the final valve positions so you can reset them after any future draining or maintenance.
Tips and common mistakes
Balance with the heating running and the system already warm, not from cold.
Never fully close a lockshield on a radiator that must stay on, or that room will never heat.
If one radiator stays cold after balancing, it may need bleeding again or the pump speed checked.
Turn off the boiler and let pipes cool before touching valves if you are unsure.
Questions
Which radiator do I balance first?
Start with the radiator nearest the boiler and work outwards along the pipe run. The closest ones need the most restriction so the furthest ones get enough flow.
Do I adjust the TRV or the lockshield to balance?
Use the lockshield valve for balancing. The TRV sets the room temperature and should be left at a normal setting while you balance.
How many turns should the lockshield be open?
There is no fixed number. Start around a quarter to half a turn on the nearest radiator and open each one slightly more as you move away from the boiler.