How to balance a forced hot-air heating system

Balance a forced hot-air system so every room gets enough heat by adjusting the dampers in the ducts. It suits any homeowner with a furnace and a basement or crawlspace full of round or rectangular ductwork. You need access to the ducts and a thermometer to check room temperatures.

YouTube video: How to Balance a Forced Hot-Air System | This Old House

Caption availability is unknown. Check the CC control in the YouTube player.

Video length
3 min 25 s
Time to do it
30 minutes
Difficulty
Easy
Steps
8

What you need

Steps

  1. Turn the thermostat up so the furnace runs and the blower pushes air through the ducts. Let the system run for about 15 minutes so temperatures settle.

  2. Walk through each room and note which ones feel too warm and which stay cold. Write the room names down so you can track changes.

  3. Find the damper on each branch duct. It is a metal lever or a wing nut on the side of the duct that opens and closes a flap inside.

  4. Close the dampers partway on the ducts feeding the warm rooms. Turn the lever so it sits across the duct to restrict flow.

  5. Open the dampers fully on the ducts feeding the cold rooms. Line the lever up with the duct so air flows freely.

  6. Check the main trunk damper near the furnace. Leave it fully open unless the whole system is overpowered.

  7. Wait an hour, then recheck room temperatures with a thermometer. Adjust the dampers a little at a time until the rooms even out.

  8. Mark each damper lever with tape and a note so you remember the setting for next season.

Tips and common mistakes

Make small changes, a quarter turn at a time, and wait before adjusting again.

Never close a damper completely on a duct that feeds a room, or you can overheat the furnace.

Check that the furnace filter is clean before balancing, since a clogged filter cuts airflow.

Keep at least a few vents open throughout the house so the blower is not strained.

Questions

How do I know which duct feeds which room?

Turn the heat on and feel each branch duct, or follow the duct from the furnace to the register in the room. Label it with tape once you know.

Can I balance a system with no dampers?

Some older systems have no dampers in the branch ducts. In that case, adjust the floor registers instead, or have a contractor add dampers.

How long does balancing take?

The adjustments take about half an hour, but you need to let the system run for an hour or more to see the effect on room temperatures.